High pressure inflation device designed to exert pressure for balloon inflation and deflation. The Encore Inflation Device assists in controlled single step balloon inflation 20cc Inflation capability, complete with pressure gauge Large printed pressure gauge dial with finger latch mechanism...
read full descriptionThe Flextome Cutting Balloon Device consists of a balloon with three to four microsurgical blades (atherotomes) mounted lengthwise on its outer surface. When the device is inflated, the atherotomes score the plaque by severing the elastic and fibrotic continuity of the vessel with tiny...
read full descriptionThe Fox sv PTA Catheter from Abbott Vascular is designed for use in challenging peripheral vessel procedures. The Fox sv Catheter incorporates OTW (Over the Wire) design a low tip profile and rapid inflation/deflation times. Sizes 2-6mm, up to 120mm length. Inserted over 0.014 or...
read full descriptionThe Glidecath 4 Fr Hydrophilic Coated Catheter has a hydrophilic coated distal tip (15 cm) for smooth passage through tortuous vasculature. The device has a double-braided stainless steel mesh middle layer, a nylon-rich polyurethane inner layer and can accommodate...
read full descriptionThe Terumo Glidewire has a hydrophilic coating for smooth, rapid movement through tortuous vessels and crossability over difficult lesions.
read full descriptionGRIP TM is a unique innovative high pressure NC balloon that has rows of focal knobs positioned across the the body of the balloon. The Focal knobs act as pressure points to treat difficult to crack plaque at the same time helping the balloon to grip, reducing the risk of slippage. ...
read full descriptionThis valve is design for haemostasis with multiple devices through the valve leaflets and can take very high pressures. We have used the valve during carotid stenting procedures and off label to provide a water tight seal for irrigation when using high pressure bags with a flexible ureteroscope....
read full descriptionHiryu is a percutaneous transluminal coronary angioplasty (PTCA) dilation catheter used for angina and other treatment. According to the manufacturer, it has high pressure resistance (to enable the widening of hardened blood vessels) and capability in reaching peripheral blood vessels.
read full descriptionThe HiWire hydrophilic guide wire from Cook Medical facilitates the placement of devices during diagnostic and interventional procedures.
read full descriptionThe IN.PACT Admiral Paclitaxel-eluting PTA Balloon Catheter from Invatec (now aquired by Medtronic) is designed for use in procedures of the superficial femoral artery. The IN.PACT Admiral has a dual-lumen shaft design, 6-folding balloon structure with "FLEXITEC" balloon material...
read full descriptionWhichMedicalDevice is a FREE resource created by clinicians for clinicians.
Registration is free and gives you unlimited access to all of the content and features of this website.
Find out more...Registration is free and gives you unlimited access to all of the content and features of Which Medical Device. Find out more...
Which Medical Device is a community of clinicians sharing knowledge and experience of the devices and procedures we use on a daily basis. We ask that our members register with us so that we can maintain the unbiased and independent nature of our content. Registration is quick and free.
We do not make your details available to any third parties nor do we send unsolicited emails to our members. You can read our Privacy Policy here.