This catheter features the benefits of a split-tip design with two round inner lumens. It has i mproved kink resistance with high flow rates and a t wo piece extension design for easy replacement of extensions. The device is MRI compatible.
read full descriptionThe ExoSeal(TM) Vascular Closure Device makes use of key technological developments to support the clinical safety* and efficacy of the closure procedure. A bioabsorbable PGA-plug (Polyglycolic Acid), is designed to close the femoral artery puncture site with minimal or no inflammation. It...
read full descriptionThis open cell balloon mounted stent from Boston is claimed to have excellent radial force. Their website compares it with 5 other selected stents. It is available in 6-10mm diameters and lengths from 17-57mm. It can be inserted through 6 and 7F sheaths (depending on stent size). ...
read full descriptionAccording to the manufacturer, i ncreased stent scaffolding at the proximal end is designed to provide optimal lumen support and 6F guide catheter compatibility. Improved tracking is intended to offer excellent deliverability. Customised balloon lengths available for each stent length are...
read full descriptionThe FastSeal Bioabsorbable Vascular Access Closure System is available in 6 Fr and 7 Fr.
read full descriptionAccording to the manufacturer, the Femoral Introducer Sheath and Hemostasis device (FISH) provides vascular closure for patients undergoing treatment for cardiovascular and peripheral disease. The FDA approved product comprises of an introducer sheath with a pre-mounted biologic material...
read full descriptionThe Femoseal by Terumo is a closure device using 3 bioabsorbable components. 2 of these are polymer dics with an inner disc deployed inside the vessel and an outer disc on the outer wall of the vessel with an absorbable locking suture joining the two. Terumo quote a median time to...
read full descriptionThe Flextome Cutting Balloon Device consists of a balloon with three to four microsurgical blades (atherotomes) mounted lengthwise on its outer surface. When the device is inflated, the atherotomes score the plaque by severing the elastic and fibrotic continuity of the vessel with tiny...
read full descriptionThe Fluency Plus Vascular Stent Graft is designed for use in the iliac and femoral arteries and consists of a self-expanding Nitinol skeleton, encapsulated within two ultrathin layers of ePTFE. The soft, atraumatic tip is tapered to fit a 0.035" guidewire, and...
read full descriptionReinforced 4F sheath combined with strong, thin-wall design provides easier insertion and eliminates the need for vascular closure device. 4F Crossover 45 cm 4F straight 45 & 100 cm Coil-reinforced Offering excellent kink resistance and a non-ovalling sheath lumen for superb flexibility......
read full descriptionA 4 Fr pulse spray thrombolysis system for pharmaco-mechanical thrombolysis. All the required components (a catheter, tip occlusion wire and variable volume hand trigger for pulse spray injection) are in a single package. The catheter length varies from 45cm (e.g. for dilaysis fistulas) to...
read full descriptionThe Fox sv PTA Catheter from Abbott Vascular is designed for use in challenging peripheral vessel procedures. The Fox sv Catheter incorporates OTW (Over the Wire) design a low tip profile and rapid inflation/deflation times. Sizes 2-6mm, up to 120mm length. Inserted over 0.014 or...
read full descriptionFustar Steerable Introducer Outstanding Design Unique tip deflection technology Combination of long sheath and guiding catheter Outstanding tip deflection technology?0-160° Precise Super Select Catheterization Save surgery time by avoiding repetitive catheter sizing...
read full descriptionThis is an updated version of the recovery filter. This nitinol (nickel-titanium alloy) filter has a conical shape with 6 legs and 6 filter wires arranged in 2 offset layers. It has elastic fixation hooks designed to allow easier removal. Maximum caval diameter for insertion is 28mm and it...
read full descriptionThis product is distributed in the UK by BVM Medical for world wide distributors please consult the manufacturer. Micro-Introducers GaltNeedleTech™’s Micro-Introducer Kits Distributed in the UK by BVM Medical provide the high quality and precision...
read full descriptionGalt's Microslide™ Pediatric Introducer line features tearaway sheath introducers, small diameter guidewires and short needles. The device is expected to be primarily used for procedures involving smaller patients including infants, children and adolescents. The 2 and 3 Fr introducers and...
read full descriptionThis product is distributed in the UK by BVM Medical. For world wide distributors please consult the manufacturer. Galt?s Speciality Guidewires are designed for interventional procedures and intended for use with diagnostic and therapeutic catheters and interventional devices within the...
read full descriptionA new advance in catheterization of uterine and pelvic arteries. Ultra-tapered distal segment with hydrophilic coating provides benefits of a microcatheter without added cost. Available in 2cm, 4cm and 6cm distal tip lengths for customized arterial placement. Flexible shaft facilitates...
read full descriptionThe Glidecath 4 Fr Hydrophilic Coated Catheter has a hydrophilic coated distal tip (15 cm) for smooth passage through tortuous vasculature. The device has a double-braided stainless steel mesh middle layer, a nylon-rich polyurethane inner layer and can accommodate...
read full descriptionThe Terumo Glidewire has a hydrophilic coating for smooth, rapid movement through tortuous vessels and crossability over difficult lesions.
read full descriptionAn excellent addition to any IR departments’ shelf, the Terumo Glidewire Advantage is a combination wire consisting of a distal 25cm hydrophilic component fused with a stiff proximal shaft (resulting in increased pushability) with spiral PTFE coating.
read full descriptionThis is a synthetic surgical glue based on cyanoacrylate with the addition of a monomer. It is biodegradable and impermeable to liquids. It seems to be more predictable and easier to use than hystoacryl (monomeric n-butyl-2-cyanoacrylate) with less likelyhood of catheter fixation....
read full descriptionInterventionalists treating patients suffering from Peripheral Vascular Disease in the Superficial Femoral Arteryand Proximal Popliteal Arteries need a flexible stent which is capable of stenting tortuous arteries. The Gore Tigris Vascular Stent has a dual component design,...
read full descriptionThis latest covered balloon expandable stent from Gore is an interesting design with independent stainless steel rings said to make it more flexible. The semi compliant balloon allows variation in stent size with inflation pressure. Balloon mounting will of course allow accurate placement....
read full descriptionThis filter is available in stainless steel or titanium variations. It is designed to reduce the tilting problems identified with the Titanium Greenfield model by using over-the-wire insertion. It also uses an alternating hook arrangement that has been shown to reduce tilt and migration. One...
read full descriptionWhichMedicalDevice is a FREE resource created by clinicians for clinicians.
Registration is free and gives you unlimited access to all of the content and features of this website.
Find out more...Registration is free and gives you unlimited access to all of the content and features of Which Medical Device. Find out more...
Which Medical Device is a community of clinicians sharing knowledge and experience of the devices and procedures we use on a daily basis. We ask that our members register with us so that we can maintain the unbiased and independent nature of our content. Registration is quick and free.
We do not make your details available to any third parties nor do we send unsolicited emails to our members. You can read our Privacy Policy here.