Page 1 of 3
Show results per page
Sort By:  A-Z / Rating / Date
Ai-Medic Company, Ltd AI-wiring system | Used in Fixation of proximal femoral fracture, Fracture fixation, Primary hip replacement, Revision hip replacement | Which Medical Device

No Editor Review

No Ratings

AI-wiring system

The AI-wiring system from Ai-Medic is a system for fixation of the greater trochanter (titanium) or fracture fixation in trauma (stainless steel). 

read full description
Stryker Dall-Miles Cable System | Used in Fixation of proximal femoral fracture, Fracture fixation, Revision hip replacement | Which Medical Device

No Editor Review

5 Stars

Dall-Miles Cable System

  • Added Jun 1, 2013
  • Manufactured by Stryker

The Dall-Miles multifilament orthopaedic cabling system from Stryker was originally designed for trochanteric reattachment. The system has plates with trochanteric hooks; a grip plate system allows capture of the wires within the plate.

read full description
Depuy Synthes Dynamic Hip Screw | Used in Fixation of proximal femoral fracture, Fracture fixation, Fracture plating | Which Medical Device

No Editor Review

No Ratings

Dynamic Hip Screw

The Dynamic Hip Screw from Depuy Synthes is intended for the fixation of proximal femoral fractures. It is indicated for per-trochanteric, lateral femoral neck fractures and some subtrochanteric fractures. Usually it is implanted after closed reduction on a fracture table under image...

read full description
Stryker Gamma3 Locking Nail System | Used in Fixation of proximal femoral fracture, Fracture fixation | Which Medical Device

No Editor Review

No Ratings

Gamma3 Locking Nail System

  • Added May 6, 2013
  • Manufactured by Stryker

The Gamma 3 Locking Nail system from Stryker is a third-generation intramedullary nailing system for the femur. Both long and short variants are available. The new nails have a proximal diameter of 15.5mm which is intended to facilitate minimally invasive surgery. The nails are manufactured...

read full description
Depuy Synthes Proximal Femoral LCP plates | Used in Fixation of proximal femoral fracture | Which Medical Device

No Editor Review

No Ratings

Proximal Femoral LCP plates

The proximal femoral locking compression plate (LCP) from Depuy-Synthes comes in a Hook Plate (to provide fixation of the trochanter) and non-hook plate version. Screws are 4.5/5.0mm, with combi-holes in the shaft allowing the placement of either. The most proximal screw hole accepts a 7.3mm...

read full description

WhichMedicalDevice is a FREE resource created by clinicians for clinicians.

Registration is free and gives you unlimited access to all of the content and features of this website.

Find out more...

Please sign in to view this content...

I have forgotten my password
Not a Member?

Registration is free and gives you unlimited access to all of the content and features of Which Medical Device. Find out more...

Why Register

Which Medical Device is a community of clinicians sharing knowledge and experience of the devices and procedures we use on a daily basis. We ask that our members register with us so that we can maintain the unbiased and independent nature of our content. Registration is quick and free.

We do not make your details available to any third parties nor do we send unsolicited emails to our members. You can read our Privacy Policy here.