This is a braided catheter with a PTFE lining available in a range of sizes from 6 to 8F and lumens of 0.070 to 0.091" The catheter has an atraumatic radio opaque tip.
read full descriptionThe MAGEC (MAGnetic Expansion Control) System from Ellipse technologies is an adjustable growing rod which can be distracted using an External Remote Controller. Constructs can be single or dual rod and distraction can be reversed if necessary. The Product Fact Sheet can be found here .
read full descriptionThis device allows the radiologist to perform angiographic intervention remote from the patient and any radiation exposure. It allows precise control of a guiding catheter, catheter and guide wire simultaneously in all planes at the touch of a few buttons. The robot controls the...
read full descriptionMagic glue form Balt is a new variation of cyanoacrylate adhesive liquid embolic agent. It is said to have delayed polymerisation with less adhesion to the microcatheter making it easier to use than conventional cyanoacrylate. It wll be interesting to see how it compares with Glubran?
read full descriptionThe Stereotaxis Magnetic Navigation System is designed to allow physicians to more navigate catheters, guidewires and other magnetic interventional devices, through the blood vessels and chambers of the heart to treatment sites and then to effect treatment. This is achieved using...
read full descriptionOffers a high level of rail support with a hydrophilic-coated polymer sleeve for smooth device delivery and vessel wall interaction. Tip Flexibility/Style: Floppy/Spring coil Tip Radiopacity: 3cm Rail Support: Super Core Material: Unibody stainless steel Coating:...
read full descriptionThe MaioRegen Biojoint System is a trilaminate matrix which is intended to be inserted into osteochondral defects and replace the missing articular cartilage. The deepest layer is hydroxyapatite, the superficial layer is equine type 1 collagen, and the intermediate layer is a mixture of the...
read full descriptionThe Mako Robotic Arm Interactive Orthopaedic System from Stryker Corporation comprises an image processing system for preoperative planning and a robotic arm to perform MAKOplasty, or robot-assisted arthroplasty of the hip and knee. The arm can control the position in space of a burr for precise...
read full descriptionThe MANTA Device is the first commercially available biomechanical vascular closure device designed specifically for large bore femoral arterial access site closure. 1 Available in 14 Fr. and 18 Fr., a single MANTA Device effectively closes femoral arterial access sites following the...
read full descriptionThe MARATHON cemented acetabulum is a cross-linked polyethylene socket for hip replacement. The device has a flange which can be trimmed after trialling and before insertion. The socket has an alignment wire which is supplied separately and should be affixed to the polyethylene component before...
read full descriptionMarathon Cross-Linked Polyethylene is a third generation cross-linked polyethylene. The manufacturing process involves 5 MRad of gamma irradiation, followed by a thermal treatment which is said to reduce free radicals in the polyethylene, enhance material consolidation and reduce the oxidative...
read full descriptionThe Maris Deep Infrapopliteal Self-Expanding Stent from Invatec (now aquired by Medtronic) is designed for use in peripheral vessel procedures. The Maris Deep is a 3.7F profile nitinol stent with OTW delivery system and 4F introducer sheath compatibility. Infrapopliteal stenting...
read full descriptionA dedicated access wire for difficult antegrade femoral access The Marsman SpeedWire® is an innovative guidewire specifically developed for easy access of the superficial femoral artery (SFA). Due to the unique and patented shape consisting of a J tip, deflection curve and...
read full descriptionThe Multi-Array Septal Catheter (MASC) is a multi-electrode catheter designed to map and ablate complex fractionated atrial electrograms (CFAE) along the left atrial septum.
read full descriptionThis product is distributed in the UK by BVM Medical for world wide distributors please consult the manufacturer. The Maslanka Grasping Forceps are an accessory to the PFM Occlusion devices in case of embolization. Key features include: ...
read full descriptionThe MatrixRIB Fixation System is designed for the fixation and stabilisation of rib fractures, fusions and osteotomies of normal and osteoporotic bone. It consists of precontoured locking plates, locking screws and splints. The plates are precontoured to fit an average rib shape...
read full descriptionThe Maxera ™ Cup from Zimmer is a large diameter ceramic acetabular component. The ceramic is Biolox delta, the design includes a 180 degree full hemisphere, with three anti-rotation fins. Large diameter heads ranging from 32mm to 48mm are available. The bearing is intended for younger...
read full descriptionSupplied by the manufacturer on a custom made basis, this is a 2-part intra-medullary device designed for arthrodesis of the knee. The components are introduced via the knee joint and then joined by a locking pin. Each nail segment can be fixed in the medullary canals with cross-locking...
read full descriptionThe Mayday Nail is a 2-part intra-medullary device designed for arthrodesis of the knee, where both components are introduced via the knee joint and joined by a locking pin. Each nail segment may be fixed in the respective medullary canals by means of cross locking screws. Additional...
read full descriptionDesigned by Morrey in 1984, this conservative bone preserving femoral component has the longest track record in short stem devices. This is a neck-retaining device. The Mayo stem has a proximal wide trapezoidal cross-section in order to gain multipoint contact within cortical bone, and is wedge...
read full descriptionThe Modular Dual Mobility acetabulum from Stryker (MDM) complements the ADM system, but is based on the Trident or Tritanium uncemented acetabular shells. The polyethylene component is manufactured from X3 polyethylene . The femoral head is either 22.2mm for smaller size shells, or 28mm. A CoCr...
read full descriptionThe Medial Rotation Knee differs from other contemporary knee designs by having a geometry which includes a spherical medical tibial condyle and a more cylindrical lateral femoral condyle. The spherical medial condyle allows rotation in flexion, whilst the smaller cylindrical lateral...
read full descriptionMediracer NCS is designed for diagnosing sensoric nerve entrapments in an outpatient settings. The device tests for Carpal Tunnel Syndrome related median nerve entrapment; disposable surface electrodes determine whether the finding is abnormal and grade its severity. Updated 22nd...
read full descriptionAn interesting device that can be switched between power modulation or temperature modulation modes. This presumably varies between the different types of ablation needle. The power modulation mode likely relies on impedence feedback such as in the cooltip device from Medtronic ad RF 3000...
read full descriptionThis new monitor from Medtronic allows continuous monitor SpO2 (Nellcor™ pulse oximetry), etCO2 (Microstream™ capnography), ECG and temperature. Also measures NiBP. Features an HL7 interface that wirelessly connects to your EMR. I saw this at BSIR 2023 and made a short video...
read full descriptionWhichMedicalDevice is a FREE resource created by clinicians for clinicians.
Registration is free and gives you unlimited access to all of the content and features of this website.
Find out more...Registration is free and gives you unlimited access to all of the content and features of Which Medical Device. Find out more...
Which Medical Device is a community of clinicians sharing knowledge and experience of the devices and procedures we use on a daily basis. We ask that our members register with us so that we can maintain the unbiased and independent nature of our content. Registration is quick and free.
We do not make your details available to any third parties nor do we send unsolicited emails to our members. You can read our Privacy Policy here.